【标题】某电站锅炉掉焦灭火分析和措施
【Title】A certain power plant boiler coke extinguishing analysis and measures
【摘要】燃煤锅炉运行中会产生底渣和飞灰,合理控制两者的比例,降低其可燃物含量并使锅炉不发生严重的结焦是电站锅炉运行调整的基本要求,但是在实际生产中一些电站锅炉经常发生严重的结焦,焦块脱落造成锅炉灭火等事故。本文主要就某电站锅炉发生的掉焦灭火事故进行分析,提出改造建议。
【Abstract】 in the operation of the coal-fired boiler slag and fly ash, reasonable control both ratio, reduce the fuel content and make the boiler does not occur serious coking is the basic requirement of the power plant boiler operation adjustment, but in the actual production in some power plant boiler often occur serious coking, focal piece fall off causing boiler fire accident, etc. This article mainly occurs in a power plant boiler focus fire accident analysis, put forward reform Suggestions.
【关键词】结焦;灭火;分析;改造
【Keywords】coking; Put out the fire; Analysis; transform
【作者】李凯 | :国家电投集团河南电力有限公司技术信息中心,河南省 郑州市 450001; |
Likai | : national electricity group technical information center of henan electric power co., LTD, henan province, zhengzhou city, 450001; |
【来源】2016年中国电机工程学会年会论文集
【出版时间】Tue Nov 15 00:00:00 CST 2016